portable spo2 monitor on stock
Product Detailed
Related Categories:Emergency & Clinics Apparatus
patient, spo2 monitor
12" color TFT display
Support 12 channel waves
ECG/RESP,NIBP,SPO2,TEMP,dual IBP,CO2,loC
CE, 13485.
Multiple-Parameters Patient Monitor
Modul Number: XDH-21L12
12" color TFT display,support 12 channel waves,
9 parameters include:
ECG/RESP,NIBP,SPO2,TEMP,dual IBP, CO2, loC.
Unique human voice alarm
Rich screen larouts:Standard, Big font, Trend table, NIBP trend,ECG full lead, OxyCRG,loC Layout
Powerful storage: maximum 720 hour graphic and tabular trends od all parameters, up to 10000NIBP review, 200 alarm event review, 2 hours of all waveforms
System software can be upgraded through network.
XDH-21L12 | |
ECG | |
1. Lead mode: | I,II,III,AVR,AVL,AVF,V |
2. Gain: | ×0.25, ×0.5, ×1, ×2 |
3. Heart Rate: Resolution: Accuracy: | 15-300bpm (Adult) 15-350bpm (Pediatric/Neonatal)1bpm±1% |
4. Bandwidth: | Diagnostic:0.05~130HzMonitor:0.5~40HzSurgery:1~20Hz |
5. Sweep Speed: | 12.5mm/s, 25mm/s, 50mm/s |
6. Pacemaker rejection: | Yes |
7. ST measurement Range: Accuracy: | -2.0~+2.0mV±0.02mV or ±10% which is greater |
SpO2 | |
1. Measure range: | 0-100% |
2. Resolution: | 1% |
3. Accuracy: | ±2%(70-100%); ±3%(40-69%);unspecified (<40%) |
4. Pulse Rate: Resolution: Accuracy: | 20-300bpm1bpm±3bpm |
NIBP | |
1. Work Mode: | Manual, Automatic, continuous |
2. Unit: | mmHg, kPa |
3. Measure range: Adult: Pediatric: Neonatal: | SYS:40-280mmHgDIA:10-220mmHgMEAN:20-240mmHgSYS:40-220mmHgDIA:10-160mmHgMEAN:20-170mmHgSYS:40-135mmHgDIA:10-100mmHgMEAN:20-110mmHg |
4. Resolution: | 1mmHg |
5. Accuracy: | Maximum Mean error:±5mmHg; Maximum Standard deviation:8mmHg |
6. Overpressure Protection: | Adult 300mmHgPediatric 240mmHgNeonatal 150mmHg |
RESP | |
1. Measure range: | Adult 0~120rpm |
Pediatric,Neonatal 0-150rpm | |
2. Resolution: | 1rpm |
3. Accuracy: | ±2% |
TEMP | |
1. channels: | 2 |
2. Measure range: | 0-50centidegree |
3. Resolution: | 0.1centidegree |
4. Accuracy: | ±0.1(25-45) centidegree, ±2(other)centidegree |
IBP(Optional) | |
1. channels: | 2 |
2. Measure range: | -50~360mmHg |
3. Accuracy: | ±2% or ±1mmHg which is greater |
CO2(Optional) | |
1. Measure range: | 0%~13% |
2. Resolution: | 1mmHg |
3. Accuracy: | ±2mmHg @ <5.0% CO2 (at ATPS) |
4. Resp: | 3-150rpm |
IoC(Optional) | |
EEG sensitivity | ±475 uV |
CMRR: | >100dB |
Input Impedance | >50M ohm |
IoC | 0-100 |
ESR | 0-100% |
EMG | 0-100 |
RECORDER (Optional) | |
1. Width: | 48mm |
2. Speed: | 25/50mm/s |
3. Channels: | 2 |
Standard configuration: | ECG, RESP, TEMP, NIBP, SpO2 |
Optional: | dual IBP, CO2, IoC, Recorder, VGA |
centidegree
portable spo2 monitor on stock